食品标法查询网  >  食品法规   >  饮料类   >  §129.20 瓶装饮用水的厂建设计(Plant construction and design)
法规搜索

§129.20 瓶装饮用水的厂建设计(Plant construction and design)

发布机构 FDA 文号
发布时间 实施时间
状态 未知状态 来源 GPO
备注 条例规定瓶装室应以坚固墙壁、天花板和自动门与其他工厂操作和贮存区域分开以减少污染,在未封闭的条件下加工操作时需采取充分措施以排除水和系统的污染,对操作间、瓶装间和容器清洗消毒区域充分换气从而降低浓度,瓶子的清洗消毒在封闭室内进行将入瓶装室前受污染的可能性降到最低,水静置、处理的房间和容器、器具、设备清洗或静置的房间不能向其它任何内部房间直接开放。


  § 129.20   Plant construction and design.

  (a) The bottling room shall be separated from other plant operations or storage areas by tight walls, ceilings, and self-closing doors to protect against contamination. Conveyor openings shall not exceed the size required to permit passage of containers.

  (b) If processing operations are conducted in other than a sealed system under pressure, adequate protection shall be provided to preclude contamination of the water and the system.

  (c) Adequate ventilation shall be provided to minimize condensation in processing rooms, bottling rooms, and in container washing and sanitizing areas.

  (d) The washing and sanitizing of containers for bottled drinking water shall be performed in an enclosed room. The washing and sanitizing operation shall be positioned within the room so as to minimize any possible post-sanitizing contamination of the containers before they enter the bottling room.

  (e) Rooms in which product water is handled, processed, or held or in which containers, utensils, or equipment are washed or held shall not open directly into any room used for domestic household purposes.

免责声明:
  • 本网站所有法规资料,都来自于网络和食品同行,内容仅供食品行业技术交流学习使用,请勿作他用,正式场合使用请购买正版。若网站内容与纸质文件相关内容不一致时,以纸质文件为准,否则由此产生的一切后果自行承担。
  • 本网站对此不承担任何技术及版权问题;如本站有相关内容侵权,请告知。
  • 未经食品标法查询网(www.foodcta.com)许可,任何网站不得非法抄袭本网站的资料、资源。